-40%

Oscilloscope DC/AC Current Probe Range 50mA-100A Peak Bandwidth -3dB 100KHz BNC

$ 187.43

Availability: 100 in stock
  • All returns accepted: Returns Accepted
  • Item must be returned within: 30 Days
  • Brand: generic
  • MPN: A622
  • Model: A622
  • Country/Region of Manufacture: China
  • Condition: New
  • Refund will be given as: Money Back
  • Restocking Fee: No
  • Return shipping will be paid by: Buyer

    Description

    Note: we'll ship this item via
    express mail service
    to USA, Canada, Australia, New Zealand, Ireland, Austria, Belgium, Denmark, Germany, France, Finland, Luxemburg, Malta, Norway, Sweden, Swiss, Spain, Italy, UK, Japan, Korea,Thailand, Malaysia, Indonesia, Philippine, Singapore.
    Clients from other countries pls contact with us in advance to confirm the different shipping charges before you order.
    1. Frequency range (-3dB)DC-100KHz
    2. The load impedance >=1MΩ and <=100pF
    3. Insert impedance 0.01Ω
    4. The maximum operating voltage 600Vrms
    5. Battery 9V alkaline battery (
    not included
    )
    It is a high performance current probe a capable of simultaneous measurement of DC and AC.
    Measurement of current is from 50mA to 100A peak, the bandwidth reaches 100KHz (-3dB).
    Two range switching (10A file and 100A file), convenient switching low current and high current measurement.
    With the power indicator light and overload indication lamp, and the use of battery power, makes the measurement more convenient.
    BNC output interface, convenient connection and oscilloscope and other equipment.
    Usually used for frequency measurement, motor drive, power supply, avionics etc.
    Electrical specifications:
    Measuring conditions: 23
    C
    +-
    5
    C
    , 20-75%RH, with conductor central in the loop.
    Range
    50mA~10A Peak
    1A~100A Peak
    Current Transfer Ratio
    100mV/A
    10mV/A
    Amplitude accuracy
    3%±5mV
    500m-40A Peak

    4%±500uV; 40-100A Peak: see Fig.2
    BW(-3dB)
    DC-100KHz (see Fig.3)
    Phase shift
    DC-65Hz: <1.5°
    DC-65Hz: <1°
    Phase shift characteristic
    see Fig.4
    Load impedance
    ≥1MΩ and ≤100pF
    Input impedance
    0.01Ω
    Noise
    6mV
    600μV
    Slew rate
    0
    .
    3V/uS
    20mV/us
    Rise time
    <3.5us
    <3.5us
    Transient response
    see Fig.5
    Square-wave response
    see Fig.6(50Hz/200mA); see Fig.7(1KHz/200mA); see Fig.8(10KHz/200mA)
    Continuous maximum input range
    see Fig.9
    Max. rated voltage
    to earth
    600Vrms
    Battery
    9V(NEDA 1604A,IEC 6LR61),
    not included
    Low battery indicator
    >6.5V ,LED Green
    Overload indicator
    Red LED indicator measuring the current is overload. Change the range.